- calcPageSize())" class="bg-gray-light inset-0 object-contain object-center w-full m-auto max-h-screen-75" :class="{ 'cursor-pointer': !fullscreen }" width="678" height="678" :loading="active!==index ? 'lazy' : 'eager'" :src="fullscreen ? image.full : image.img" x-transition.opacity.duration.500ms />
KNX T-UP Touch CH
Temperature sensor and controller with touch keys
Indoor temperature sensor for KNX. With display/touch buttons, controller for heating
Highlights
-
-
Room controller with glass surface
-
-
Heating control
-
-
Glass surface
- - Integrated temperature sensor
The Temperature Sensor KNX T-UP Touch CH measures the room temperature. The indoor sensor can receive an external measured value via the bus and process it with own data to overall temperature value (mixed value). TheKNX T-UP Touch offers two push buttons that may be used for changing the ambient temperature (target value), for switching between operating modes or as free programmable bus push buttons. The KNX T-UP Touch provides adjustable threshold values. The threshold value outputs and further communication objects can be linked by AND and OR logic gates. Additional y, an integrated actuating variable comparator can compare and output values that are received via communication objects. The sensor has integrated PI controller for a heating/cooling system. The integrated display shows the own values and data received from the bus (e.g. date, time). The device is completed with a frame of the switching series installed in the building and thus merges with the interior.
Models:
N° 70633 KNX T-UP Touch CH, pure white RAL 9010
N° 70634 KNX T-UP Touch CH, jet black RAL 9005
Delivery without frame
- Measurement of temperature
- Mixed value from own measured values and external values (proportions can be set in percentage)
- Display 1-3 rows (own values or values received from the bus) or display of temperature control (see Mode display and manual temperature controller)
- 2 push buttons. Configuration as bus push button or for changing ambient temperature and switching between operating modes (see Change ambient temperature with the buttons)
- PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
- Threshold values can be adjusted per parameter or via communication objects: 3 × temperature
- 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 16 logic inputs in the form of communication objects, may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
- 2 actuating variable comparators for output of minimum, maximum or average values. Each with 5 inputs (for values received via communication objects)
- Configuration is made using the KNX software ETS
Housing | Glass, plastic material |
Colours | • similar to RAL 9010 pure white • similar to RAL 9005 jet black |
Mounting | Installation in inlet box |
Protection category | IP 20 |
Dimensions | Housing approx. 60x 60 (W x H, mm), mounting depth approx. 8 mm |
Total weight | approx. 60 g |
Ambient temperature | Operation 0…+55°C, storage -10…+60°C |
Ambient air humidity | max. 5... 95% RH, avoid bedewing |
Operating voltage | KNX bus voltage |
Bus current | max. 10 mA |
Data output | KNX +/- bus terminal plug |
Group addresses | max. 254 |
Allocations | max. 254 |
Communication objects | 180 |
Temperature measurement range | 0…+50°C |
-
Housing with display
-
Mounting adapter with screws
-
Data sheet with installation instruction German, English, French, Italian, Spanish)
-
Manual (German, English, French, Italian, Spanish) as download
-
Product file (German, English, French, Italian, Spanish) as download
You will need in addition (not supplied):
- Cover frame (for insert 60 x 60 mm) and mounting plate (77 mm) for swiss installation standard
- Inlet box
Filter by language:
ZIP
Item No.: 70629, 70628, 70633, 70634
Languages:
RTF
Item No.: 70633, 70634
Languages:
The Temperature Sensor KNX T-UP Touch CH measures the room temperature. The indoor sensor can receive an external measured value via the bus and process it with own data to overall temperature value (mixed value). TheKNX T-UP Touch offers two push buttons that may be used for changing the ambient temperature (target value), for switching between operating modes or as free programmable bus push buttons. The KNX T-UP Touch provides adjustable threshold values. The threshold value outputs and further communication objects can be linked by AND and OR logic gates. Additional y, an integrated actuating variable comparator can compare and output values that are received via communication objects. The sensor has integrated PI controller for a heating/cooling system. The integrated display shows the own values and data received from the bus (e.g. date, time). The device is completed with a frame of the switching series installed in the building and thus merges with the interior.
Models:
N° 70633 KNX T-UP Touch CH, pure white RAL 9010
N° 70634 KNX T-UP Touch CH, jet black RAL 9005
Delivery without frame
- Measurement of temperature
- Mixed value from own measured values and external values (proportions can be set in percentage)
- Display 1-3 rows (own values or values received from the bus) or display of temperature control (see Mode display and manual temperature controller)
- 2 push buttons. Configuration as bus push button or for changing ambient temperature and switching between operating modes (see Change ambient temperature with the buttons)
- PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
- Threshold values can be adjusted per parameter or via communication objects: 3 × temperature
- 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 16 logic inputs in the form of communication objects, may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
- 2 actuating variable comparators for output of minimum, maximum or average values. Each with 5 inputs (for values received via communication objects)
- Configuration is made using the KNX software ETS
Housing | Glass, plastic material |
Colours | • similar to RAL 9010 pure white • similar to RAL 9005 jet black |
Mounting | Installation in inlet box |
Protection category | IP 20 |
Dimensions | Housing approx. 60x 60 (W x H, mm), mounting depth approx. 8 mm |
Total weight | approx. 60 g |
Ambient temperature | Operation 0…+55°C, storage -10…+60°C |
Ambient air humidity | max. 5... 95% RH, avoid bedewing |
Operating voltage | KNX bus voltage |
Bus current | max. 10 mA |
Data output | KNX +/- bus terminal plug |
Group addresses | max. 254 |
Allocations | max. 254 |
Communication objects | 180 |
Temperature measurement range | 0…+50°C |
-
Housing with display
-
Mounting adapter with screws
-
Data sheet with installation instruction German, English, French, Italian, Spanish)
-
Manual (German, English, French, Italian, Spanish) as download
-
Product file (German, English, French, Italian, Spanish) as download
You will need in addition (not supplied):
- Cover frame (for insert 60 x 60 mm) and mounting plate (77 mm) for swiss installation standard
- Inlet box
Filter by language:
ZIP
Item No.: 70629, 70628, 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
Item No.: 70633, 70634
Languages:
RTF
Item No.: 70633, 70634
Languages: