- calcPageSize())" class="bg-gray-light inset-0 object-contain object-center w-full m-auto max-h-screen-75" :class="{ 'cursor-pointer': !fullscreen }" width="678" height="678" :loading="active!==index ? 'lazy' : 'eager'" :src="fullscreen ? image.full : image.img" x-transition.opacity.duration.500ms />
KNX S4-B10 | KNX S2-B6 230 V
Actuators with multifunctional outputs and inputs
Multifunctional KNX Actuator with Integrated Facade Control for Drives of Awnings, Blinds, Roller Shutters, Windows and for Switchable Consumer Loads like Lights. Outputs 230 V AC. With Digital Inputs
Highlights
-
-
Universal actuators, can be used to control motors/drives and for switching
-
-
Automatic functions for sun shading control (blinds, shutters, awnings)
-
-
Automatic functions for natural ventilation (windows)
-
-
Scene control
- - Buttons on the device facilitate commissioning
The Actuators KNX S4-B10 and KNX S2-B6 230 V with integrated facade control have multifunctional outputs, pairs of buttons and monitoring LEDs. Each of the multifunctional outputs can connect to either a drive with Up/Down control (blinds, awnings, shutters, windows) or two switchable devices (On/Off for light and ventilation). The connected drives and devices can be operated directly on the actuator
or via connected hand switches.
The automation can be specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definition (e.g. manual-automatic). Scenes can be saved and called up via the bus (scene control with 16 scenes per drive).
Binary inputs can be used either for direct operation (e.g. hand switches) or as bus switches (or also for e.g. alarm notifications). The desired behaviour can be defined precisely through selection of the response times in Standard, Comfort or Deadman mode.
Models:
N° 70546 KNX S4-B10 230 V, 4 multifunctional outputs, 10 binary inputs (successor to 70137, 70530)
N° 70548 KNX S2-B6 230 V, 2 multifunctional outputs, 6 binary inputs (successor to 70381, 70531)
- Multifunctional outputs each for a 230 V drive (shade, window) or for connecting two switchable devices (light, fan); KNX S4-B10: 4 outputs | KNX S2-B6: 2 outputs
- Keypad with button pairs and status LEDs
- Binary inputs for use as hand switches or as bus switches with variable
voltage (12...80 V DC, 12...240 V AC)
KNX S4-B10: 10 inputs | KNX S2-B6: 6 inputs - Automatic runtime measurement of the drives for positioning (including fault notification object)
- Position feedback (movement position, also slat position for blinds)
- Position storage (movement position) via 1-bit object (storage and call-up e.g. via button)
- Control via internal or external automation
- Integrated shade control for each drive output (with slat tracking according to sun position for blinds)
- Scene control for movement position with 16 scenes per drive (also slat position for blinds)
- Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
- Blocking objects and alarm notifications have different priorities, so safety functions always take precedence (e.g. wind block)
- Manual or automatic priority setting via time or communication object
- 5 Safety objects for each channel
- Short time restriction (movement command blocked) and movement limitation
- Configuration is made using the KNX software ETS 5
General: | |
Housing | plastic |
Colour | white |
Assembly in distribution boxes or small housings according to DIN VDE 0603 on 35 mm mounting rails according to DIN EN 60715 |
|
Degree of protection [according to] | IP20 [DIN EN 60 529] |
Dimensions (W x H x D) | 107mm × 88mm × 60mm |
division units | 6 |
Total weight | ≈ 360g |
Ambient temperature | -5...+45°C |
Ambient humidity (RH) (non-con-densing) | 0...95% |
Storage temperature | -25...+70°C |
Protective class | II |
Overvoltage category | III |
Degree of contamination | 2 |
KNX bus: | |
Medium | TP1-256 |
Configuration mode | S-Mode |
Group addresses maximum | 1024 |
Assignments maximum | 1024 |
Communication objects | 567 / 295 |
Rated voltage | 30V DC SELV |
Power consumption | 10mA |
Connection KNX plug-in terminal Conductor diameter Stripping length |
0.6…0.8mm s 5mm |
Duration after bus voltage restoration until data is received |
≈ 5 s |
Inputs: | |
Binary input • Input voltage range • Contact current [at] "N/–" contacts are common reference potential for all inputs +24V contacts (DC voltage supply for push-button) can be loaded up to 30 mA in total |
10 × / 6 × 12...80 V DC, 12...230 V AC 0.24mA [24 V DC]; 1.3mA [230V AC] |
Connection spring terminals Conductor cross-section • solid • fine-stranded • fine-stranded with ferrule with and without plastic sleeve Stripping length One wire per terminal |
0.2…2.5 mm² 0.2…1.5 mm² 0.25…1.5 mm² 7.5 mm |
Maximum cable length | 50m |
Supply: | |
Voltage | 230V AC / 50 Hz |
Power consumption max. typ. |
3.5 W 1 W |
Multifunctional outputs: | |
2 Closer contacts for 1 drive (Up/Down) or 2 devices (On/Off) with integrated fuse Breaking capacity: 1500 A, slowblow, Rated current: 4 A connected with L of the supply |
4 × / 2 × Micro Contact (μ) HT4A |
Minimum current for runtime measurement [AC effective] (drives) |
200 mA |
Motors | 500VA |
LEDi (LED lamps with an integrated ballast) |
15W |
Electronic ballasts | 36W |
Connection of supply and outputs: | |
Spring terminals Conductor cross-section • solid • fine-stranded • fine-stranded with ferrule without plastic sleeve • fine-stranded with ferrule with plastic sleeve Stripping length 16 A per terminal One wire per terminal |
0.2…4 mm² 0.2…2.5 mm² 0.25…2.5 mm² 0.25…1.5 mm² 7 mm |
- Actuator for rail mounting
- Data sheet with installation instruction (German, English, French, Italian, Spanish)
- Manual (German, English, French, Italian, Spanish) as download
Filter by language:
Item No.: 70546, 70548
Languages:
RTF
Item No.: 70546, 70548
Languages:
ZIP
Item No.: 70546
Languages:
ZIP
Item No.: 70546, 70548
Languages:
Item No.: 70546, 70548
Languages:
The Actuators KNX S4-B10 and KNX S2-B6 230 V with integrated facade control have multifunctional outputs, pairs of buttons and monitoring LEDs. Each of the multifunctional outputs can connect to either a drive with Up/Down control (blinds, awnings, shutters, windows) or two switchable devices (On/Off for light and ventilation). The connected drives and devices can be operated directly on the actuator
or via connected hand switches.
The automation can be specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definition (e.g. manual-automatic). Scenes can be saved and called up via the bus (scene control with 16 scenes per drive).
Binary inputs can be used either for direct operation (e.g. hand switches) or as bus switches (or also for e.g. alarm notifications). The desired behaviour can be defined precisely through selection of the response times in Standard, Comfort or Deadman mode.
Models:
N° 70546 KNX S4-B10 230 V, 4 multifunctional outputs, 10 binary inputs (successor to 70137, 70530)
N° 70548 KNX S2-B6 230 V, 2 multifunctional outputs, 6 binary inputs (successor to 70381, 70531)
- Multifunctional outputs each for a 230 V drive (shade, window) or for connecting two switchable devices (light, fan); KNX S4-B10: 4 outputs | KNX S2-B6: 2 outputs
- Keypad with button pairs and status LEDs
- Binary inputs for use as hand switches or as bus switches with variable
voltage (12...80 V DC, 12...240 V AC)
KNX S4-B10: 10 inputs | KNX S2-B6: 6 inputs - Automatic runtime measurement of the drives for positioning (including fault notification object)
- Position feedback (movement position, also slat position for blinds)
- Position storage (movement position) via 1-bit object (storage and call-up e.g. via button)
- Control via internal or external automation
- Integrated shade control for each drive output (with slat tracking according to sun position for blinds)
- Scene control for movement position with 16 scenes per drive (also slat position for blinds)
- Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
- Blocking objects and alarm notifications have different priorities, so safety functions always take precedence (e.g. wind block)
- Manual or automatic priority setting via time or communication object
- 5 Safety objects for each channel
- Short time restriction (movement command blocked) and movement limitation
- Configuration is made using the KNX software ETS 5
General: | |
Housing | plastic |
Colour | white |
Assembly in distribution boxes or small housings according to DIN VDE 0603 on 35 mm mounting rails according to DIN EN 60715 |
|
Degree of protection [according to] | IP20 [DIN EN 60 529] |
Dimensions (W x H x D) | 107mm × 88mm × 60mm |
division units | 6 |
Total weight | ≈ 360g |
Ambient temperature | -5...+45°C |
Ambient humidity (RH) (non-con-densing) | 0...95% |
Storage temperature | -25...+70°C |
Protective class | II |
Overvoltage category | III |
Degree of contamination | 2 |
KNX bus: | |
Medium | TP1-256 |
Configuration mode | S-Mode |
Group addresses maximum | 1024 |
Assignments maximum | 1024 |
Communication objects | 567 / 295 |
Rated voltage | 30V DC SELV |
Power consumption | 10mA |
Connection KNX plug-in terminal Conductor diameter Stripping length |
0.6…0.8mm s 5mm |
Duration after bus voltage restoration until data is received |
≈ 5 s |
Inputs: | |
Binary input • Input voltage range • Contact current [at] "N/–" contacts are common reference potential for all inputs +24V contacts (DC voltage supply for push-button) can be loaded up to 30 mA in total |
10 × / 6 × 12...80 V DC, 12...230 V AC 0.24mA [24 V DC]; 1.3mA [230V AC] |
Connection spring terminals Conductor cross-section • solid • fine-stranded • fine-stranded with ferrule with and without plastic sleeve Stripping length One wire per terminal |
0.2…2.5 mm² 0.2…1.5 mm² 0.25…1.5 mm² 7.5 mm |
Maximum cable length | 50m |
Supply: | |
Voltage | 230V AC / 50 Hz |
Power consumption max. typ. |
3.5 W 1 W |
Multifunctional outputs: | |
2 Closer contacts for 1 drive (Up/Down) or 2 devices (On/Off) with integrated fuse Breaking capacity: 1500 A, slowblow, Rated current: 4 A connected with L of the supply |
4 × / 2 × Micro Contact (μ) HT4A |
Minimum current for runtime measurement [AC effective] (drives) |
200 mA |
Motors | 500VA |
LEDi (LED lamps with an integrated ballast) |
15W |
Electronic ballasts | 36W |
Connection of supply and outputs: | |
Spring terminals Conductor cross-section • solid • fine-stranded • fine-stranded with ferrule without plastic sleeve • fine-stranded with ferrule with plastic sleeve Stripping length 16 A per terminal One wire per terminal |
0.2…4 mm² 0.2…2.5 mm² 0.25…2.5 mm² 0.25…1.5 mm² 7 mm |
- Actuator for rail mounting
- Data sheet with installation instruction (German, English, French, Italian, Spanish)
- Manual (German, English, French, Italian, Spanish) as download
Filter by language:
Item No.: 70546, 70548
Languages:
RTF
Item No.: 70546, 70548
Languages:
ZIP
Item No.: 70546
Languages:
ZIP
Item No.: 70548
Languages:
Item No.: 70546, 70548
Languages:
Item No.: 70546, 70548
Languages:
Item No.: 70546, 70548
Languages:
Item No.: 70546, 70548
Languages:
Item No.: 70546, 70548
Languages: