KNX eTR gl
Temperature Sensor with Automatic Control
KNX heating controller with temperature sensor
The Temperature Sensor KNX eTR gl measures the room temperature. The indoor sensor can receive an external measured value via the bus and process it with own data to an overall temperature value (mixed value).
The KNX eTR gl has a integrated PI controller for a heating/cooling system.
Models:
N° 71300 KNX eTR gl, signal white RAL 9003
N° 71302 KNX eTR gl, jet black RAL 9005
- Measurement of temperature
- Mixed values from own measured value and external values (proportions can be set in percentage)
- PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
Configuration is made using the KNX software ETS
General | |
Casing | Genuine glass, plastic |
Colours | • similar to RAL 9003 signal white • similar to RAL 9005 deep black |
Casing Genuine glass, plastic | |
Installation | on the wall or on device socket according to DIN 49073 |
Dimensions | housing approx. 81.5 mm x 81.5 mm (W x H), mounting depth approx. 12 mm |
Total weight | approx. 70 g |
Ambient temperature | -5…+45 °C |
Ambient humidity | 5...95 % RH, non-condensing |
Storage temperature | -30…+85 °C |
Overvoltage category | III |
Degree of contamination | 2 |
KNX bus | |
Medium | TP1-256 |
Configuration mode | S-Mode |
Group addresses | max. 254 |
Assignments | max. 254 |
Communication objects | 41 |
Nominal voltage | 30 V SELV |
Power consumption maximum | 10 mA |
Connection Conductor diameter Stripping length |
KNX plug terminals 0.6…0.8 mm² s 5 mm |
Connection Conductor diameter Stripping length |
Spring-loaded terminals • rigid and flexible conductors 0.2...0.75 mm² • flexible conductors with ferrules 0.25...0.34 mm² 7...9 mm |
Duration after bus voltage restoration until data is received |
approx. 5 seconds |
Sensor | |
Temperature measurement range |
-5…+60 °C |
- Temperature Sensor with mounting • 4 screw anchors 4 × 20 mm, 4 flat head screws 3 × 25 mm
- KNX plug-in terminal
- Data sheet with installation instruction German, English, French, Italian, Spanish)
- Manual (German, English, French, Italian, Spanish) as download
- Product file (German, English, French, Italian, Spanish) as download
Filter by language:
RTF
Item No.: 71300, 71302
Languages:
ZIP
Item No.: 71300, 71302
Languages:
ZIP
Item No.: 70650, 70651, 71312, 71060, 71062, 71112, 71110, 71092, 71090, 71162, 71160, 71300, 71302, 71310, 71190, 71192, 30190
Languages:
The Temperature Sensor KNX eTR gl measures the room temperature. The indoor sensor can receive an external measured value via the bus and process it with own data to an overall temperature value (mixed value).
The KNX eTR gl has a integrated PI controller for a heating/cooling system.
Models:
N° 71300 KNX eTR gl, signal white RAL 9003
N° 71302 KNX eTR gl, jet black RAL 9005
- Measurement of temperature
- Mixed values from own measured value and external values (proportions can be set in percentage)
- PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
Configuration is made using the KNX software ETS
General | |
Casing | Genuine glass, plastic |
Colours | • similar to RAL 9003 signal white • similar to RAL 9005 deep black |
Casing Genuine glass, plastic | |
Installation | on the wall or on device socket according to DIN 49073 |
Dimensions | housing approx. 81.5 mm x 81.5 mm (W x H), mounting depth approx. 12 mm |
Total weight | approx. 70 g |
Ambient temperature | -5…+45 °C |
Ambient humidity | 5...95 % RH, non-condensing |
Storage temperature | -30…+85 °C |
Overvoltage category | III |
Degree of contamination | 2 |
KNX bus | |
Medium | TP1-256 |
Configuration mode | S-Mode |
Group addresses | max. 254 |
Assignments | max. 254 |
Communication objects | 41 |
Nominal voltage | 30 V SELV |
Power consumption maximum | 10 mA |
Connection Conductor diameter Stripping length |
KNX plug terminals 0.6…0.8 mm² s 5 mm |
Connection Conductor diameter Stripping length |
Spring-loaded terminals • rigid and flexible conductors 0.2...0.75 mm² • flexible conductors with ferrules 0.25...0.34 mm² 7...9 mm |
Duration after bus voltage restoration until data is received |
approx. 5 seconds |
Sensor | |
Temperature measurement range |
-5…+60 °C |
- Temperature Sensor with mounting • 4 screw anchors 4 × 20 mm, 4 flat head screws 3 × 25 mm
- KNX plug-in terminal
- Data sheet with installation instruction German, English, French, Italian, Spanish)
- Manual (German, English, French, Italian, Spanish) as download
- Product file (German, English, French, Italian, Spanish) as download
Filter by language:
RTF
Item No.: 71300, 71302
Languages:
Item No.: 71300, 71302
Languages:
Item No.: 71300, 71302
Languages:
Item No.: 71300, 71302
Languages:
Item No.: 71300, 71302
Languages:
Item No.: 71300, 71302
Languages:
Item No.: 71300, 71302
Languages:
ZIP
Item No.: 71300, 71302
Languages:
ZIP
Item No.: 70650, 70651, 71312, 71060, 71062, 71112, 71110, 71092, 71090, 71162, 71160, 71300, 71302, 71310, 71190, 71192, 30190
Languages: