KNX AQS/TH-UP Touch
Sensor for CO2, Temp., Humidity with Touch Buttons
Combined indoor sensor for KNX with sensors for CO2, temperature, humidity. With display/touch buttons, controller for heating and ventilation
The Sensor KNX AQS/TH-UP Touch measures CO2 concentration, temperature and humidity and calculates the dew point. The sensor can receive external measured values via the bus and process them with the own data to overall values (mixed values, e. g. room average). The KNX AQS/TH-UP Touch offers two push buttons that may be used for changing the ambient temperature (target value), for switching between operating modes or as free programmable bus push buttons.
The KNX AQS/TH-UP Touch provides switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked by AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects.
Integrated PI controllers allows for control of a ventilation (depending on CO2 concentration and air humidity) and a heating/cooling system (depending on temperature). The KNX AQS/TH-UP Touch can emit a warning to the bus as soon as the area of optimum comfort (according to DIN 1946) is left.
The integrated display shows the own values and data received from the bus (e.g. date, time). The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.
Models:
N° 70620 KNX AQS/TH-UP Touch, pure white
N° 70619 KNX AQS/TH-UP Touch, black
Delivery without frame
Replacement for 70239-70242
- Measurement of CO2 concentration of the air, of temperature and air humidity (absolute and relative), calculation of the dew point
- Mixed values from own measured values and external values (proportions can be set in percentage)
- Display 1-3 rows (own values or values received from the bus) or display of temperature control (see Mode display and manual temperature controller, page 2)
- 2 push buttons. Configuration as bus push button or for changing ambient temperature and switching between operating modes (see Change ambient temperature with the buttons, page 2)
- PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
- PI controller for ventilation depending on humidity and CO2 concentration: dehumidification/humidification (one step) or dehumidification (one or two step)
- Threshold values can be adjusted per parameter or via communication objects: 3 × temperature, 2 × humidity, 4 × CO2
- 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs in the form of communication objects, may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
- 2 actuating variable comparators for output of minimum, maximum or average values. Each with 5 inputs (for values received via communication objects)
- Configuration is made using the KNX software ETS
General | Casing Genuine glass, plastic |
Colours (similar) | RAL 9010 (white) RAL 9005 (black) |
Degree of protection (after assembly) | IP20 |
Size (W × H × D) | ≈ 55 mm × 55 mm × 35 mm |
Supporting ring (W × H) | ≈ 71 mm × 71 mm |
Mounting depth | ≈ 7 mm |
Total weight | ≈ 53 g |
Ambient temperature | 0…+45 °C |
Ambient humidity (RH) (non-condensing) |
0...95 % |
Storage temperature | -10...+60 °C |
Overvoltage category | III |
Degree of contamination | 2 |
KNX bus | |
Medium | TP1-256 |
Configuration mode | S-Mode |
Group addresses max. | 254 |
Assignments max. | 254 |
Communication objects | 196 |
Nominal voltage | 30 V SELV |
Power consumption max. | 20 mA |
Connection KNX plug-in terminals | Conductor diameter: 0.6…0.8 mm s Stripping length: 5 mm |
Duration after bus voltage restoration until data is received approx. |
6 s |
Sensors | |
CO2 measurement range | 400...9 000 ppm |
Temperature measurement range | -5…+60 °C |
Humidity measurement range | 0...95 |
- Housing
- Supporting ring
- KNX plug-in terminal
- Data Sheet with installation instruction (German, English, French, Italian, Spanish)
- Manual (German, English, French, Italian, Spanish) as download
- Product file (German, English, French, Italian, Spanish) as download
Required accessories: (not included in the scope of delivery) •
- Windproof device socket according to DIN EN IEC 60670-1 and DIN 49073
- Frame (for insert 55 x 55 mm), compatible to the switch scheme used in the building
Filter by language:
ZIP
Item No.: 70619
Languages:
RTF
ZIP
Item No.: 70619, 70620, 70643, 70639
Languages:
Item No.: 70619, 70620
Languages:
The Sensor KNX AQS/TH-UP Touch measures CO2 concentration, temperature and humidity and calculates the dew point. The sensor can receive external measured values via the bus and process them with the own data to overall values (mixed values, e. g. room average). The KNX AQS/TH-UP Touch offers two push buttons that may be used for changing the ambient temperature (target value), for switching between operating modes or as free programmable bus push buttons.
The KNX AQS/TH-UP Touch provides switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked by AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects.
Integrated PI controllers allows for control of a ventilation (depending on CO2 concentration and air humidity) and a heating/cooling system (depending on temperature). The KNX AQS/TH-UP Touch can emit a warning to the bus as soon as the area of optimum comfort (according to DIN 1946) is left.
The integrated display shows the own values and data received from the bus (e.g. date, time). The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.
Models:
N° 70620 KNX AQS/TH-UP Touch, pure white
N° 70619 KNX AQS/TH-UP Touch, black
Delivery without frame
Replacement for 70239-70242
- Measurement of CO2 concentration of the air, of temperature and air humidity (absolute and relative), calculation of the dew point
- Mixed values from own measured values and external values (proportions can be set in percentage)
- Display 1-3 rows (own values or values received from the bus) or display of temperature control (see Mode display and manual temperature controller, page 2)
- 2 push buttons. Configuration as bus push button or for changing ambient temperature and switching between operating modes (see Change ambient temperature with the buttons, page 2)
- PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
- PI controller for ventilation depending on humidity and CO2 concentration: dehumidification/humidification (one step) or dehumidification (one or two step)
- Threshold values can be adjusted per parameter or via communication objects: 3 × temperature, 2 × humidity, 4 × CO2
- 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs in the form of communication objects, may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
- 2 actuating variable comparators for output of minimum, maximum or average values. Each with 5 inputs (for values received via communication objects)
- Configuration is made using the KNX software ETS
General | Casing Genuine glass, plastic |
Colours (similar) | RAL 9010 (white) RAL 9005 (black) |
Degree of protection (after assembly) | IP20 |
Size (W × H × D) | ≈ 55 mm × 55 mm × 35 mm |
Supporting ring (W × H) | ≈ 71 mm × 71 mm |
Mounting depth | ≈ 7 mm |
Total weight | ≈ 53 g |
Ambient temperature | 0…+45 °C |
Ambient humidity (RH) (non-condensing) |
0...95 % |
Storage temperature | -10...+60 °C |
Overvoltage category | III |
Degree of contamination | 2 |
KNX bus | |
Medium | TP1-256 |
Configuration mode | S-Mode |
Group addresses max. | 254 |
Assignments max. | 254 |
Communication objects | 196 |
Nominal voltage | 30 V SELV |
Power consumption max. | 20 mA |
Connection KNX plug-in terminals | Conductor diameter: 0.6…0.8 mm s Stripping length: 5 mm |
Duration after bus voltage restoration until data is received approx. |
6 s |
Sensors | |
CO2 measurement range | 400...9 000 ppm |
Temperature measurement range | -5…+60 °C |
Humidity measurement range | 0...95 |
- Housing
- Supporting ring
- KNX plug-in terminal
- Data Sheet with installation instruction (German, English, French, Italian, Spanish)
- Manual (German, English, French, Italian, Spanish) as download
- Product file (German, English, French, Italian, Spanish) as download
Required accessories: (not included in the scope of delivery) •
- Windproof device socket according to DIN EN IEC 60670-1 and DIN 49073
- Frame (for insert 55 x 55 mm), compatible to the switch scheme used in the building
Filter by language:
ZIP
Item No.: 70619
Languages:
RTF
Item No.: 70619
Languages:
ZIP
Item No.: 70619, 70620, 70643, 70639
Languages:
Item No.: 70619, 70620
Languages:
Item No.: 70619, 70620
Languages:
Item No.: 70619, 70620
Languages:
Item No.: 70619, 70620
Languages:
Item No.: 70619, 70620
Languages:
Item No.: 70619, 70620
Languages: