KNX TH-UP gl
Temperature/Humidity Sensor
Combined indoor sensor for KNX with sensors for temperature and humidity. With controller for heating and ventilation
The Sensor KNX TH-UP gl measures the temperature and humidity and calculates the dew point. The sensor can receive external measured values via the bus and process them with the own data to overall values (mixed values, e. g. room average).
The KNX TH-UP gl provides switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked by AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects.
Integrated PI controllers allows for control of a ventilation (depending on air humidity) and a heating/cooling system (depending on temperature).
The KNX TH-UP gl can emit a warning to the bus as soon as the area of optimum comfort (according to DIN 1946) is left.
Models:
N° 70622 KNX TH-UP gl, black
N° 70623 KNX TH-UP gl, pure white
Delivery without frame
Replacement for 70362-70365
- Measurement of temperature and air humidity (absolute and relative), calculation of the dew point
- Mixed values from own measured values and external values (proportions can be set in percentage)
- PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
- PI controller for ventilation depending on humidity: dehumidification/humidification (one step) or dehumidification (one or two step)
- Threshold values can be adjusted per parameter or via communication objects: 3 × temperature, 2 × humidity
- 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs in the form of communication objects, may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
- 2 actuating variable comparators for output of minimum, maximum or average values. Each with 5 inputs (for values received via communication objects)
- Configuration is made using the KNX software ETS
General | Casing Genuine glass, plastic |
Colours (similar) | RAL 9010 (white) RAL 9005 (black) |
Degree of protection (after assembly) |
IP20 |
Size (W × H × D) | ≈ 55 mm × 55 mm × 35 mm |
Supporting ring (W × H) | ≈ 71 mm × 71 mm |
Mounting depth | ≈ 7 mm |
Total weight | ≈ 53 g |
Ambient temperature | -5…+45 °C |
Ambient humidity (RH) (non-condensing) |
0...95 % |
Storage temperature | -10...+60 °C |
Overvoltage category | III |
Degree of contamination | 2 |
KNX bus | |
Medium | TP1-256 |
Configuration mode | S-Mode |
Group addresses max. | 254 |
Assignments max. | 254 |
Communication objects | 158 |
Nominal voltage | 30 V SELV |
Power consumption max. | 10 mA |
Connection KNX plug-in terminals | Conductor diameter: 0.6…0.8 mm s Stripping length: 5 mm |
Duration after bus voltage restoration until data is received approx. |
6 s |
Sensors | |
Temperature measurement range | -5…+60 °C |
Humidity measurement range | 0...95 % |
- Housing
- Supporting ring
- KNX plug-in terminal
You will need additionally (not included):
- Windproof device socket according to DIN EN IEC 60670-1 and DIN 49073
- Frame (for insert 55 x 55 mm), compatible to the switch scheme used in the building
Filter by language:
ZIP
Item No.: 70622, 70623, 70644, 70645
Languages:
RTF
Item No.: 70622, 70623
Languages:
RTF
The Sensor KNX TH-UP gl measures the temperature and humidity and calculates the dew point. The sensor can receive external measured values via the bus and process them with the own data to overall values (mixed values, e. g. room average).
The KNX TH-UP gl provides switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked by AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects.
Integrated PI controllers allows for control of a ventilation (depending on air humidity) and a heating/cooling system (depending on temperature).
The KNX TH-UP gl can emit a warning to the bus as soon as the area of optimum comfort (according to DIN 1946) is left.
Models:
N° 70622 KNX TH-UP gl, black
N° 70623 KNX TH-UP gl, pure white
Delivery without frame
Replacement for 70362-70365
- Measurement of temperature and air humidity (absolute and relative), calculation of the dew point
- Mixed values from own measured values and external values (proportions can be set in percentage)
- PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
- PI controller for ventilation depending on humidity: dehumidification/humidification (one step) or dehumidification (one or two step)
- Threshold values can be adjusted per parameter or via communication objects: 3 × temperature, 2 × humidity
- 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs in the form of communication objects, may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
- 2 actuating variable comparators for output of minimum, maximum or average values. Each with 5 inputs (for values received via communication objects)
- Configuration is made using the KNX software ETS
General | Casing Genuine glass, plastic |
Colours (similar) | RAL 9010 (white) RAL 9005 (black) |
Degree of protection (after assembly) |
IP20 |
Size (W × H × D) | ≈ 55 mm × 55 mm × 35 mm |
Supporting ring (W × H) | ≈ 71 mm × 71 mm |
Mounting depth | ≈ 7 mm |
Total weight | ≈ 53 g |
Ambient temperature | -5…+45 °C |
Ambient humidity (RH) (non-condensing) |
0...95 % |
Storage temperature | -10...+60 °C |
Overvoltage category | III |
Degree of contamination | 2 |
KNX bus | |
Medium | TP1-256 |
Configuration mode | S-Mode |
Group addresses max. | 254 |
Assignments max. | 254 |
Communication objects | 158 |
Nominal voltage | 30 V SELV |
Power consumption max. | 10 mA |
Connection KNX plug-in terminals | Conductor diameter: 0.6…0.8 mm s Stripping length: 5 mm |
Duration after bus voltage restoration until data is received approx. |
6 s |
Sensors | |
Temperature measurement range | -5…+60 °C |
Humidity measurement range | 0...95 % |
- Housing
- Supporting ring
- KNX plug-in terminal
You will need additionally (not included):
- Windproof device socket according to DIN EN IEC 60670-1 and DIN 49073
- Frame (for insert 55 x 55 mm), compatible to the switch scheme used in the building
Filter by language:
ZIP
Item No.: 70622, 70623, 70644, 70645
Languages:
RTF
Item No.: 70622
Languages:
Item No.: 70622, 70623
Languages:
Item No.: 70622, 70623
Languages:
Item No.: 70622, 70623
Languages:
Item No.: 70622, 70623
Languages:
Item No.: 70622, 70623
Languages:
Item No.: 70622, 70623
Languages:
RTF
Item No.: 70622
Languages: